Nine-month angiographic and two-year clinical follow-up of polymer-free sirolimus-eluting stent versus durable-polymer sirolimus-eluting stent for coronary artery disease: the Nano randomized trial

Nine-month angiographic and two-year clinical follow-up of polymer-free sirolimus-eluting stent versus durable-polymer sirolimus-eluting stent for coronary artery disease: the Nano randomized trial

  • 分类:学术论文
  • 作者:
  • 来源:
  • 发布时间:2016-08-12 09:00
  • 访问量:

【概要描述】First generation drug-eluting stents (DES) were associated with a high incidence of late stent thrombosis (ST), mainly due to delayed healing and re-endothelization by the durable polymer coating. This study sought to assess the safety and efficacy of the Nano polymer-free sirolimus-eluting stent (SES) in the treatment of patients with de novo coronary artery lesions.

Nine-month angiographic and two-year clinical follow-up of polymer-free sirolimus-eluting stent versus durable-polymer sirolimus-eluting stent for coronary artery disease: the Nano randomized trial

【概要描述】First generation drug-eluting stents (DES) were associated with a high incidence of late stent thrombosis (ST), mainly due to delayed healing and re-endothelization by the durable polymer coating. This study sought to assess the safety and efficacy of the Nano polymer-free sirolimus-eluting stent (SES) in the treatment of patients with de novo coronary artery lesions.

  • 分类:学术论文
  • 作者:
  • 来源:
  • 发布时间:2016-08-12 09:00
  • 访问量:
详情

  BACKGROUND: First generation drug-eluting stents (DES) were associated with a high incidence of late stent thrombosis (ST), mainly due to delayed healing and re-endothelization by the durable polymer coating. This study sought to assess the safety and efficacy of the Nano polymer-free sirolimus-eluting stent (SES) in the treatment of patients with de novo coronary artery lesions.

  METHODS: The Nano trial is the first randomized trial designed to compare the safety and efficacy of the Nano polymer-free SES and Partner durable-polymer SES (Lepu Medical Technology, Beijing, China) in the treatment of patients with de novo native coronary lesions. The primary endpoint was in-stent late lumen loss (LLL) at 9-month follow-up. The secondary endpoint was major adverse cardiac events (MACE), a composite of cardiac death, myocardial infarction or target lesion revascularization.

  RESULTS: A total of 291 patients (Nano group: n = 143, Partner group: n = 148) were enrolled in this trial from 19 Chinese centers. The Nano polymer-free SES was non-inferior to the Partner durable-polymer DES at the primary endpoint of 9 months (P < 0.001). The 9-month in-segment LLL of the polymer-free Nano SES was comparable to the Partner SES (0.34 ± 0.42) mm vs. (0.30 ± 0.48) mm, P = 0.21). The incidence of MACE in the Nano group were 7.6% compared to the Partner group of 5.9% (P = 0.75) at 2 years follow-up. The frequency of cardiac death and stent thrombosis was low for both Nano and Partner SES (0.8% vs. 0.7%, 0.8% vs. 1.5%, both P = 1.00).

  CONCLUSIONS: In this multicenter randomized Nano trial, the Nano polymer-free SES showed similar safety and efficacy compared with the Partner SES in the treatment of patients with de novo coronary artery lesions. Trials in patients with complex lesions and longer term follow-up are necessary to confirm the clinical performance of this novel Nano polymer-free SES.

中国生物材料学会材料生物力学分会换届大会圆满召开
2022 12-08

中国生物材料学会材料生物力学分会换届大会圆满召开

精准植入 完美心舒——冠脉支架定位系统
2022 11-27

精准植入 完美心舒——冠脉支架定位系统

北京阿迈特与北京航空航天大学联合参与生物医疗器械国家急需高层次人才培养专项
2022 11-26

北京阿迈特与北京航空航天大学联合参与生物医疗器械国家急需高层次人才培养专项

公司信息

北京阿迈特医疗器械有限公司

Beijing Advanced Medical Technologies,Ltd.Inc.

联系我们

地址:北京市大兴区永旺西路26号院中关村医疗器械园11号楼

电话:010-6297-7955             邮箱:amt@ametcorp.com

联系我们

地址:北京市大兴区永旺西路26号院中关村医疗器械园11号楼

电话:010-6297-7955             

邮箱:amt@ametcorp.com